WIDE INPUT RANGE UPS WITH 0.99 POWER FACTOR
Orion Pfc H Series of Online UPS using triple conversion topology to provide clean and stable power supply to your Equipment’s. In This topology the current Draw from line also clean with very low THD. These UPS are 1 or 3 phase input and 1 phase output type, Optional Built in Isolation transformer may be provided if ordered. Orion Pfc H Series UPS provide better output power with high performance and efficiency for critical applications. The unique Eco Mode Provide up to 99% efficiency.
Configuration
- 1 Phase input , 1 Phase output
Applications
- Datacenters, industrial machinery, instrument and measurement, process monitoring and control, security and transport systems etc.
- Hospital, airport, OT’s
- Superstore, CCTV, Flex Banner Printing Machines etc.


Main Features
- True Double-conversion online UPS
- DSP technology guarantees high performance
- Rack/Tower design
- User-friendly and easy-shift LCD display
- Wide input voltage range (100-300 VAC)
- 50Hz/60Hz frequency converter mode
- Active Input power factor correction 0.99
- Output power factor 0.9
- 50/60 Hz Frequency Converter Mode
- Emergency power off function (EPO)
- ECO mode operation for energy saving
- Generator compatible
- High overload capability and enhanced short circuit protection
- SNMP/USB/RS-232 multiple communications
- 3-stage smart charging design
- Maximum 5A extended Charging available for long run model
- Selectable output voltage: 200-240VAC
- Laser printer and ultrasound system load acceptable
- Isolation transformer is available as option
MODEL | ORION Pfc H 6KVA | ORION Pfc H 10KVA | ||
PHASE | Single Phase Input and Single Phase Output With Ground | |||
Capacity | 6000 VA 5400W | 10000VA 9000W | ||
INPUT PARAMETERS | ||||
Input Voltage Range at 50% load | 110- 300VAC ±5 % | |||
Input Voltage Range at 100% load | 175- 300VAC ±5 % | |||
Nominal Voltage | 200/208/220/230/240 VAC | |||
Frequency Range | 45-55Hz or (55-65Hz)** | |||
Power Factor | ≥0.99 at Nominal Voltage 100% Load | |||
Harmonic Distortion(THDi) | ≤7% at full load with linear load and battery fully charged | |||
OUTPUT PARAMETERS | ||||
Output Voltage | 200/208/220/230/240 VAC or (100/110/115/120/127 VAC)** | |||
Output Voltage Regulation | ±1 %, (±3 %)** | |||
Frequency Range (Batt. Mode) | 50Hz ±0.1 % or (60Hz ±0.1 %)** | |||
Frequency Range (Synchronized Mode) | 47 to 53 Hz or (57 to 63Hz)** | |||
Transfer Time | AC to Battery 0 ms, Inverter to Bypass 0 ms typical | |||
Waveform | Pure Sine wave on inverter | |||
Current Crest Ration | 3:1 | |||
Total Harmonic Distortion (THDu) | ≤2% THD(Linear Load), ≤5% THD(Non Linear Load) or ≤4% THD(Linear Load)**, ≤7% THD(Non Linear Load)** | |||
Over Load ( Run On AC Line *) | 100 ~ 110%: 10 Min; 110 ~ 130%: 1 Min; > 130%: 1 Sec | |||
Over Load ( Battery Mode) | 100 ~ 110%: 30 Sec; 110 ~ 130%: 10 Sec; > 130%: 1 Sec | |||
EFFECIEANCY | ||||
Battery Mode | ≥0.88% or (≥0.82%)** | |||
Eco Mode | ≥0.96% or (≥0.87%)** | |||
AC Mode | ≥0.91% or (≥0.85%)** | |||
BATTERY | ||||
Battery Numbers | 18-20 Nos. 12V | |||
Battery Float Charging Voltage | 273 VDC (Based on batteries of 20 Nos.) | |||
Long Run Model (External Battery Connections) Max Charging Current | 4 Amps Selectable | |||
Long Run Model (External Battery Connections) Battery Capacity | Up to 100 Ah | |||
Standard Model (Internal 7Ah 12V Batteries) Max Charging Current | 1.0 Amps | |||
Standard Model (Internal 7Ah 12V Batteries) Internal Battery Recharge Time | 7 Hrs up 90% Charged | 9 Hrs up 90% Charged | ||
INDICATORS on LED & LCD | ||||
Ups Status, Load Level, Battery Level, Input /Output Voltage, Discharge Time, And Fault Alarm | ||||
ALARM | ||||
Battery Mode | Beep Every 5 Seconds | |||
Low Battery Alarm | Beep Every 2 Seconds | |||
Over Load Alarm | Beep Every 1 Seconds | |||
Fatal Fault/Error | Continuous Beep | |||
ENVIRONMENTAL | ||||
Operating Humidity and Temperature | 0-95% RH Non Condensing at 0-40 ℃ | |||
Noise Level | ≤ 58 dB @ 1Mtrs. | ≤ 60 dB @ 1Mtrs. | ||
COMmUNICATION | ||||
Optional SNMP | Remote Management Via SNMP and Web Browser | |||
RS-232 Com Port / USB | Support all window Linux and Mac Optional Monitoring Software via 3rd party software | |||
*Capacity and Current handling of UPS degraded On Low Line Voltage **110V, 60Hz Voltage and Frequency Converter Mode with optional step down output transformer @Regulation 3% #We take utmost care to make specification however crosscheck before ordering for specifications ##Due to continuous development The specification may be changed so crosscheck before ordering |