WIDE INPUT RANGE UPS WITH 0.9 POWER FACTOR
Orion Pfc L Series of Online UPS using triple conversion topology to provide clean and stable power supply to your Equipment’s. In This topology the current Draw from line also clean with very low THD. These UPS are 1 phase input and 1 phase output type, Optional Built in Isolation transformer may be provided if ordered. Orion Pfc L Series UPS provide better output power with high performance and efficiency for critical applications. The unique Eco Mode Provide up to 99% efficiency. Optional Programmable Output socket may be provided, these sockets are switch off in case of run on battery with programmable level.
Configuration
- 1 Phase input , 1 Phase output
Applications
- Server, Test and measurement instrument.
- Ultrasound Machine, Recording Studio, Table top Pick and Place Machines.
- Superstore, CCTV. Smart TV, Music System, Recording Studio etc.



Main Features
- True Triple-conversion online UPS
- Wide input voltage range (110-300 VAC, 55-150 VAC)
- Input power factor correction 0.99
- Output power factor 0.9
- 50/60 Hz Frequency Converter Mode
- Programmable power management outlets
- Emergency power off function (EPO)
- ECO mode operation for energy saving
- Very high surge immunity up to 7KV, 13KA, 1300J
- Generator compatible
- High overload capability and enhanced short circuit protection
- SNMP/USB/RS-232 multiple communications
- 3-stage smart charging design
- Maximum 8A extended Charging available for long run model
- Selectable output voltage: 200-240VAC, 100-127VAC
- Laser printer and ultrasound system load acceptable
MODEL | ORION Pfc L 1KVA | ORION Pfc L 1.5KVA | ORION Pfc L 2KVA | ORION Pfc L 3KVA |
PHASE | Single Phase Input and Single Phase Output With Ground | |||
Capacity | 1000VA 900W | 1500VA 1350W | 2000VA 1800W | 3000VA 2700W |
INPUT PARAMETERS | ||||
Input Voltage Range at 50% load | (55-150VAC ±5 %)** or 110- 300VAC ±5 % | |||
Input Voltage Range at 100% load | (80-150VAC ±5 %)** or 160- 300VAC ±5 % | |||
Nominal Voltage | (100/110/115/120/127 VAC)** or 200/208/220/230/240 VAC | |||
Frequency Range | (55-65Hz)** or 45-55Hz | |||
Power Factor | ≥0.99 at Nominal Voltage 100% Load | |||
Harmonic Distortion(THDi) | ≤5% at full load with linear load and battery fully charged | |||
OUTPUT PARAMETERS | ||||
Output Voltage | (100/110/115/120/127 VAC)** or 200/208/220/230/240 VAC | |||
Output Voltage Regulation | ±1 % | |||
Frequency Range (Batt. Mode) | 50Hz ±0.1 % or (60Hz ±0.1 %)** | |||
Frequency Range (Synchronized Mode) | (57 to 63Hz)** or 47 to 53 Hz | |||
Transfer Time | AC to Battery 0 ms, Inverter to Bypass 4 ms typical | |||
Waveform | Pure Sine wave | |||
Current Crest Ration | 3:1 | |||
Total Harmonic Distortion (THDu) | ≤2% THD(Linear Load), ≤5% THD(Non Linear Load) | |||
Over Load ( Run On AC Line *) | 100 ~ 110%: 10 Min; 110 ~ 130%: 1 Min; > 130%: 1 Sec | |||
Over Load ( Battery Mode) | 100 ~ 110%: 30 Sec; 110 ~ 130%: 10 Sec; > 130%: 1 Sec | |||
EFFECIEANCY | ||||
Battery Mode | ≥0.89% | ≥0.90% | ||
Eco Mode | ≥0.97% | |||
AC Mode | ≥0.90% | ≥0.91% | ||
BATTERY | ||||
Battery Numbers | 2 Nos. 12V or 3 Nos. 12V | 3 Nos. 12V | 6 Nos. 12V | 8 Nos. 12V or 8 Nos. 12V |
Battery Charging Voltage | 27.4 VDC or 41.0 VDC ±1 % | 41.0 VDC ±1 % | 82.1 VDC ±1 % | 82.1 VDC or 109.6 VDC ±1 % |
Long Run Model (External Battery Connections) Max Charging Current | 1/2/4/6/8 Amps Selectable | |||
Long Run Model (External Battery Connections) Battery Capacity | Up to 100 Ah | |||
Standard Model (Internal 7Ah 12V Batteries) Max Charging Current | 1.5 Amps | |||
Standard Model (Internal 7Ah 12V Batteries) Internal Battery Recharge Time | 4Hrs up 90% Charged | |||
INDICATORS on LED & LCD | ||||
Ups Status, Load Level, Battery Level, Input /Output Voltage, Discharge Time, And Fault Alarm | ||||
ALARM | ||||
Battery Mode | Beep Every 5 Seconds | |||
Low Battery Alarm | Beep Every 2 Seconds | |||
Over Load Alarm | Beep Every 1 Seconds | |||
Fatal Fault/Error | Continuous Beep | |||
ENVIRONMENTAL | ||||
Operating Humidity and Temperature | 20-95% RH Non Condensing at 0-40 ℃ | |||
Noise Level | ≤ 50 dB @ 1Mtrs. | |||
COMMUNICATION | ||||
Optional SNMP | Remote Management Via SNMP and Web Browser | |||
RS-232 Com Port / USB | Support all window Linux and Mac Optional Monitoring Software via 3rd party software | |||
*Capacity and Current handling of UPS degraded On Low Line Voltage **110 Volt 60Hz Model #We take utmost care to make specification however crosscheck before ordering for specifications ##Due to continuous development The specification may be changed so crosscheck before ordering |